Sha FENG Dandan LIU Juan LUO Qing LI Tao MO Zheng LIU Xiaonan ZOU
Abstract [Objectives] An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established for simultaneous determination of 26 antibiotics in the water around landfills.
[Methods] After an HLB solid-phase extraction column was activated, and a water sample, which was adjusted with phosphoric acid to a pH of (2±0.5) and added with 500 mg of disodium EDTA, was loaded, and 5 ml of water and 20% methanol water was added for washing. Next, 10 ml of elution solution was added for elution, and the collected eluate was evaporated under reduced pressure at 40 ℃ to near dryness, and 1 ml of reconstitution solution was added to a constant volume. An ACQUITY UPLC BEH C18 (100 mm×2.1 mm, 2.6 μm) chromatographic column was adopted for LC separation by gradient elution with 0.1% formic acid aqueous solution-acetonitrile as the mobile phase. For MS detection, the MRM mode was adopted for collection, and the positive and negative ion modes were switched for simultaneous determination, and the internal standard method was used for quantification.
[Results] The correlation coefficient R2 was greater than 0.99 in the linear range of each target substance. The limits of detection ranged from 0.15 to 3.00 ng/L, and the limits of quantitation were between 0.80 and 10.00 ng/L, and the recoveries ranged from 77.9% to 104.85%.
[Conclusions] The method has high sensitivity, good accuracy and strong practical value.
Key words Landfill; Antibiotics; Ultra high performance liquid chromatography-tandem mass spectrometry
DOI:10.19759/j.cnki.2164-4993.2024.02.010
Antibiotics refer to a class of secondary metabolites that are produced by microorganisms or higher animals and plants in the process of life activities and have anti-pathogen or other activity or artificially-synthesized analogues[1-3]. Antibiotics enter the environment through various channels such as sewage treatment plants and landfills[4-5]. Long-term "pseudo-persistent" antibiotics will not only produce toxicity to organisms, but also induce resistance genes and enhance human drug resistance, thus causing long-term potential risks to human health and the entire ecosystem. Domestic waste landfills are the final places for stacking solid waste, and landfill leachate accompanies the whole life cycle of the landfill operation. At present, China has gained more knowledge on the research of antibiotic pollution in surface runoff of rivers and lakes[6-10]. In this study, a landfill site was selected as a typical source of pollution, and surface water and groundwater around the landfill site was collected as the research objects, in which 26 typical antibiotics with high detection rates in water bodies were detected. A rapid ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of antibiotics was established by focusing on optimizing the enrichment of pH value during solid-phase extraction, chromatographic conditions and MS parameters. The method has a wide linear range, good sensitivity and high accuracy. The method was successfully applied to the analysis of water samples around the actual landfill site, providing another reliable analysis method for simultaneous determination of various endocrine disruptors in the water around landfill sites, which has strong practical value.
Materials and Methods
Experimental instruments and reagents
Instrument: Ultra-high performance liquid chromatography-tandem massspectrometry (AB 4500, Allen-Bradley, USA); MFV-24 nitrogen blowing instrument (Guangzhou Detai Instrument Technology Co., Ltd.); solid-phase extraction device (Oasis MCX, 500 mg, 6cc, Waters, USA); Milli-Q ultra-pure water instrument (Millipore, USA); TG16W high-speed centrifuge (Changsha Pingfan Instrument and Apparatus Co., Ltd.); 0.45 μM microporous filter membrane and solid-phase extraction small column (Dikma Technologies).
Standards: Sulfadiazine, sulfamethoxazole, sulfathiazole, sulfamerazine, sulfisoxazole, sulfamethythiadiazole, sulfadimidine, prinzone, sulfaquinoxaline, sulfamonomethoxine, sulfadimethoxypyrimidine, sulfadoxine, enrofloxacin, ciprofloxacin, norfloxacin, ofloxacin, pefloxacin, lomefloxacin, sarafloxacin, danofloxacin, oxytetracycline, tetracycline, doxycycline, aureomycin, enoxacin, sulfisomidine, sulfadoxine-D3, sulfadimethoxine-D6, norfloxacin-D5, ciprofloxacin-D8 and enrofloxacin-D5, all purchased from Shanghai Anpel Laboratory Technologies Co., Ltd.; methanol (chromatographically pure), acetonitrile (chromatographically pure) and formic acid (chromatographically pure), purchased from Merck KGaA; ultrapure water.
Preparation of solutions
Preparation of standard stock solution: First, a 0.005 0 g of solid standard sample was accurately weighed with an electronic balance and dissolved with methanol. Next, the obtained solution was added in a 5 ml brown glass bottle to prepare a standard stock solution with a concentration of 1 mg/ml, which was sealed and stored in a refrigerator at 4 ℃ for later use.
Preparation of standard intermediate solution: First, 100 μl of 1 mg/ml standard stock solution was pipetted into a 10 ml volumetric flask with a pipette of 1-100 μl. Next, the transferred solution was diluted with methanol to prepare a standard solution with a concentration of 10 μg/ml.
Preparation of standard working solution: Different volumes of the 10 μg/ml standard intermediate solutions of the 26 target compounds were accurately transferred into different 10 ml volumetric flasks. Next, mixed standard solutions with different concentrations were prepared by diluting with 20% methanol water.
Elution solution: Methanol: ethyl acetate: ammonia (150:150:6).
Reconstitution solution:Water:methanol:acetonitrile:formic acid (40:5:5:0.05).
Phosphate buffer solution: 19.3 g sodium phosphate monohydrate +10 ml phosphoric acid, with pH adjusted to 2.
Collections of samples
In July 2022, 13 surface water samples were collected from the vicinity of the urban landfill site in Dejiang County, Tongren City. At each sampling point, a 1 L brown hard glass bottle was rinsed three times, and then groundwater (shallow groundwater) 10-30 cm below the water surface was collected in the monitoring well. The pH value of the water sample was adjusted to a value equal to or lower than 3 with concentrated sulfuric acid, and it was transported to the laboratory for refrigeration at 1-5 ℃ in the dark. All samples were treated and analyzed within 48 h.
Pretreatment of samples
Extraction: Each water sample was stood still, and a 500 ml of water sample was added with 50 μl of internal standards and adjusted with phosphoric acid to a pH of (2±0.5). Next, 500 mg of disodium EDTA was added.
Purification: An HLB column (500 mg, 6 ml) was placed in a solid-phase extraction device, and 6 ml of methanol and 6 ml of water were added. After discarding the effluent, a liquid to be purified was added into the small column, which was then added with 5 ml of water, and rinsed with 20% methanol water. Next, 10 ml of elution solution was added for elution, and the eluate was collected. The collected eluate was evaporated under reduced pressure at 40 ℃ to near dryness, and 1 ml of reconstitution solution was added to a constant volume. The obtained solution was filtered through a microporous filter membrane to get a filtrate for analysis by instruments.
LC and MS analysis conditions
An ACQUITY UPLC BEH C18 (100 mm×2.1 mm, 2.6 μm) column was used to separate target objects. The separation was carried out with a column temperature at 35 ℃, a sample injection volume of 2 μl, and a flow rate at 0.4 ml/min. The mobile phase C was 0.1% formic acid, and the mobile phase B was 100% acetonitrile. The gradient elution was started with 98% C for 0 min, followed by 98%-90% C in 0-1.5 min, 90%-90% C in 1.5-2.0 min, 90%-75% C in 2.0-2.5min, 75%-50% C in 2.5-4.5 min, 50%-98% C in 4.5-4.6 min, and 90% C in 4.6-5.5min. For MS detection, the time window of MS was divided by the MRM mode to collect positive and negative ions. An electrospray ionization source (ESI) was used in the positive ion mode. Other parameters were as follows: curtain gas pressure (CUR) 30 psi, collision gas (CAD) 9, electrospray voltage 4 500 V, auxiliary gas 1 pressure (GS1) 55 psi, auxiliary gas 2 pressure (GS2) 55 psi, interface heating gas (IHe): On, auxiliary heating gas temperature 550 ℃, and ion source temperature 150 ℃. Specific parameters are shown in Table 1.
Results and Analysis
Optimization of chromatographic conditions
In this study, the separation effects of ACQUITY UPLC BEH C18 (50 mm×2.1 mm, 1.7 μm) and ACQUITY UPLC BEH C18 (100 mm×2.1 mm, 2.6 μm) with different lengths were compared. The results showed that the 50 mm column was too short, and the resolution of the 26 antibiotics was not good, while the 100 mm chromatographic column was better. In order to obtain chromatographic peaks well separated with good peak shapes, the separation effects using acetonitrile and methanol as mobile phases were compared in this study. When methanol was used as the mobile phase, the resolution and peak shapes of some substances were not good, and the sensitivity of some substances was reduced, but the above situation did not occur in acetonitrile. The mobile phase (ultrapure water) did not achieve a high response to quinolones, so an attempt was made by adding 0.1% formic acid to the mobile phase (ultrapure water), which improved the response to quinolones. A chromatogram with good peak shapes, strong signals and good separation effects was achieved for all 26 antibiotics. The total ion chromatogram of 26 antibiotics is shown in Fig. 1.
Sha FENG et al. Study on Detection of Antibiotic Contents in Water around Landfill Sites
Drawing of working curves
In this study, the mixed standard solution of the 26 antibiotics was diluted with 20% methanol aqueous solution, and prepared into a series of mixed standard solutions with mass concentrations of 10, 50, 80, 100, 200 and 500 ng/ml, respectively. The concentration of internal standard substance was 50 ng/ml. Working curves were drawn taking the area of quantitative ion mass spectrum peak of corresponding antibiotic as the ordinate and the mass concentration as the abscissa. The linear equations and regression coefficients are shown in Table 2. From the table, it can be seen that there was a good linear relation between the peak areas and mass concentrations of the 24 target substances, and the linear correlation coefficient R2 of each substance was higher than 0.99.
Recoveries and limits of detection
The mixed standard solutions of 26 endocrine disruptors were accurately added to 500 ml of ultra-pure water and Watsons purified water, respectively, to carry out a recovery test, and the recoveries and precision of the method were investigated. The spiked concentration levels were low (5.00 ng/L), medium (20.00 ng/L) and high (100.00 ng/L). The limits of detection ranged from 0.15 to 3.00 ng/L, and the limits of quantitation were between 0.80 and 10.00 ng/L, and the recoveries ranged from 77.9% to 104.85%. The results are shown in Table 3.
Actual sample analysis
The determination method established in this study was applied to the analysis of antibiotics in samples from 13 locations around the landfill site in Dejiang County, Tongren City. Three antibiotics were detected in total, and the detection data are shown in Table 4. Among them, ofloxacin had the highest detection frequency, and was detected at 8 detection points, with a detection rate of 61.5%. The detection concentration of sulfadimidine was the highest, with a value of 0.99 μg/L. The results indicated that this analysis method has good practical value for the determination of antibiotics in water samples around landfill sites.
Conclusions and Discussion
This study established an LC-MS/MS analysis method that could simultaneously detect the contents of 26 antibiotics in the water surrounding the landfill site. The samples were enriched by an HLB solid-phase extraction column and then determined by LC-MS. The limits of detection ranged from 0.15 to 3.00 ng/L, and the limits of quantitation were between 0.80 and 10.00 ng/L, and the recoveries ranged from 77.9% to 104.85%. Three antibiotics were detected in the actual samples. Among them, ofloxacin had the highest detection frequency, and was detected at 8 detection points, with a detection rate of 61.5%. The detection concentration of sulfadimidine was the highest, with a value of 0.99 μg/L.
The results indicated that the method has high sensitivity and good accuracy. This study provides a rapid, accurate and reliable analysis method for the determination of antibiotics in the water around landfill sites, which has strong practical value.
References
[1] NIU Y, AN S, CHEN K, et al. A Review of current status and analysis methods of antibiotic contamination in groundwater in China (2012-2021)[J]. Rock and Mineral Analysis, 2023, 42(1): 39-58. (in Chinese).
[2] YAO LJ, MO L, ZHUANG X, et al. Residual and risk assessment of antibiotics in water and sediments of typical drinking water sources in Hainan Province[J]. Asian Journal of Ecotoxicolog, 2022, 17(5): 349-361. (in Chinese).
[3] FU XY, LI XY, YANG M, et al. Antibiotic monitoring and ecological risk assessment in ecologically clean small watersheds in Liaoning Province[J]. Environmental Monitoring and Forewarning, 2022, 14(5): 114-119. (in Chinese).
[4] YANG C, TONG L, MA NJ, et al. Distribution characteristics and influencing factors of antibiotics in water and sediments of Honghu Lake[J]. Safety and Environmental Engineering, 2022, 29(5): 78-90. (in Chinese).
[5] YANG QF, ZANG JX, FU CW, et al. Antibiotic pollution in water environment in typical regions of China[J]. Occupation and Health, 2022, 38(9): 1291-1296. (in Chinese).
[6] ZHU M, TANG WY, HUANG DM, et al. Research progress of antibiotic residues and environmental impacts in surface water[J]. Journal of Green Science and Technology, 2022, 24(2): 63-67. (in Chinese).
[7] LI JL, WANG M, HU FW, et al. Antibiotic pollution characteristics and ecological risk assessment in Jinjiang River Basin, Jiangxi Province [J]. Environmental Science, 2022, 43(8): 4064-4073. (in Chinese).
[8] JU ZJ, ZHAO XY, CHEN H, et al. The characteristics of spatial distribution and environmental risk assessment for Quinolones antibiotics in the aquatic environment of Shijiazhuang City[J]. Acta Scientiae Circumstantiae, 2021, 41(12): 4919-4931. (in Chinese).
[9] ZHAO FQ, GAO H, LI RJ, et al. Occurrences and risk assessment of antibiotics in water bodies of major rivers in Bohai Rim Basin[J]. China Environmental Science, 2022, 42(1):109-118. (in Chinese).
[10] LI FJ, GAO L, LI LY, et al. Contamination characteristics and ecological risk assessment of antibiotics in the third drain of Ningxia[J]. Environmental Science, 2022, 43(3):1394-1403. (in Chinese).