孔德伟 孙其珩
摘要:悬挑脚手架作为高层建筑施工中被广泛运用的作业平台,其结构特点、搭设方式与普通的落地脚手架有所不同。针对悬挑脚手架的特点,文章以某型钢悬挑脚手架工程为例,运用模糊故障树分析方法,分析了悬挑脚手架在搭设、使用与拆除阶段中可能导致架体坍塌的风险因素,并提出相应的防范措施。
Abstract: Cantilever scaffold is a work platform which is widely used in high-rise building construction, its structural features and erection way are different from common ground scaffold. According to the characteristics of cantilever scaffold, this article utilizes the fuzzy fault tree analysis method, analyzes the risk factors which might cause the collapse of scaffold in the phase of the build-up, use and removal based on a steel cantilever scaffold project, and puts forward the corresponding preventive measures.
关键词:悬挑脚手架;脚手架坍塌;模糊故障树;施工风险分析
Key words: cantilevered scaffold;scaffold collapse;fuzzy fault tree;construction risk analysis
中图分类号:TM753 文献标识码:A 文章编号:1006-4311(2017)01-0005-03
2.6 防范措施
①在悬挑脚手架搭设阶段,应当采用刚性连墙件使架体与建筑物可靠连接,连墙件的安装应随脚手架搭设同步进行,不得滞后安装;此外,连墙件应靠脚手架主节点设置,设置间距应当符合设计与规范要求。
在悬挑脚手架搭设时,应保证固定于主体结构楼面的悬挑钢梁应有良好的抗拔脱能力。型钢悬挑梁内锚段的末端应采用2 个及以上的几型锚固螺栓或U型钢筋锚环与建筑物梁、板可靠固定,在结构梁、板浇筑混凝土之前,几型锚固螺栓或U形钢筋锚环应预埋至梁、板的底层钢筋位置,并且与梁、板的底层钢筋绑扎或焊接牢固。
此外,型钢悬挑梁外挑段的末端应设置能够使悬挑梁与脚手架立杆可靠连接的固定点,固定点距离悬挑梁端部不应小于100mm,防止脚手架立杆发生滑移脱落。
②在悬挑脚手架使用阶段,应保证脚手架作业层上的施工荷载符合设计要求,不得超载。悬挑脚手架架体严禁悬挂起重设备,并且不得将混凝土输送管、模板支撑架、缆风绳等物件固定在架体上,以防止架体受到额外的荷载。
③在悬挑脚手架拆除阶段,应保证架体的拆除有序进行。悬挑脚手架应当由上而下逐层拆除,严禁上下两层同时进行拆除作业;连墙件的拆除作业应当与架体拆除同时进行,严禁在拆除架体之前先将连墙件整层或数层拆除。
3 结论
①本文通过模糊故障树分析方法,确定了型钢悬挑脚手架在搭设、使用和拆除过程中可能导致架体坍塌的基本事件及其模糊概率,并根据这些基本事件的模糊概率,较为准确地描述出型钢悬挑脚手架坍塌事故的发生概率,同时能在一定程度上允许有描述的误差。
②脚手架作业层荷载、连墙件的设置与拆除、悬挑梁锚固、脚手架立杆与悬挑梁的固定等,是对型钢悬挑脚手架坍塌事故的发生概率影响较大的基本事件。因此在施工过程中,应从这些基本事件入手,加强对悬挑脚手架坍塌事故的防范。
参考文献:
[1]王文.型钢悬挑脚手架工程施工中存在的问题及对策[J].建筑安全,2013(01):42-44.
[2]赵艳萍,贡文伟.模糊故障树分析及其应用研究[J].中国安全科学学报,2001(06):44-48.
[3]李青,陆廷金,李宁萍,张玉柱.三角模糊数的模糊故障树分析及其应用[J].中国矿业大学学报,2000(01):56-59.
[4]韦家增.故障树分析和模糊理论在机械故障诊断中的应用研究[D].合肥工业大学,2002.
[5]刘沐宇,荆武,张睿智.基于模糊故障树理论的双壁钢围堰水中墩施工风险分析[J].土木建筑与环境工程,2014(06):34-40.