Minimum alveolar concentration based anesthesia in high altitude and anesthetic overdose:result needs cautious acceptance

2019-07-11 01:10:32
Medical Gas Research 2019年2期

Dear Editor,

Maintenance of adequate depth of general anesthesia is very important as lower dose can lead to awareness in one hand,and higher dose can lead to delayed awakening1and increased cost in the other hand.Higher altitude affects the partial pressure of gases and,therefore,the minimum alveolar concentration (MAC) guided anesthetic depth management becomes more critical and challenging.In this line,the article2published in your esteemed journal,evaluating the MAC guided anesthesia in context to anesthetic overdose judged by bi-spectral index (BIS) values,has been read with great interest.At first,we should congratulate the authors for their commendable job and brilliant hypothesis.Meta-analysis does indicate that BIS can improve anesthetic delivery and recovery from anesthesia,3and the authors' hypothesis,comparison of MAC with BIS in higher altitude and conclusion in favor of BIS-guided anesthesia in higher altitude,2can be helpful.However,a few facts and methodology needs to be considered before coming to a conclusion that MAC guided anesthesia leads to overdosing in very high numbers of cases and MAC and BIS values do not have good relationships,as found in their study.

The authors clearly mention,cite the references and agree that the MAC value depends on the demographic parameters.In fact,each decade of age affects MAC by 6%.4Therefore,the MAC monitored is not the actual MAC for the patient until the age of the patient is taken into account,in other terms,if MACage is not monitored.As standard MAC is defined for male patients aged 40 years,all anesthesia machines display the MAC for a 40-year person,unless the age of the patient is entered in the machine/gas monitor.A study has shown that 96.67% volatile anesthetic based general anesthesia were conducted without entering the birth year/age of the patient.5This minor deficit led to 79.41% of the observed MACs as incorrect; 55.88% patients were potentially under-dosed whereas 23.53% were overdosed.5As the authors have not mentioned about the use of age-specific MAC in the study,it can be presumed that it was not done,which indicates that the MAC value noted by them was actually a MAC value of 40-year person,not for the actual age of the patient.If the age/birth year is not entered in the machine/monitor,the MAC displayed corresponds to MACage only in the age range of 36-45 years.5The mean age of 36.3 ± 13.5 years of the cohort studied by the authors indicates that a good number of patients were on either side of 36-45 years of age.This also explains the authors finding that all patients older than 60 years and 65% of the patients between 36-59 years had deep BIS levels in their study when anesthesia was guided by MAC.2The effect of MAC monitoring with the age entered in the monitor is displayed in Figure 1.Moreover,the MAC range (0.8-1.2) taken as adequate level/depth needs validation too,especially whether it corresponds to 40-60 BIS values before we label the range as adequate and compare.

There is no doubt that the authors have done a great job by showing the limitations of MAC guided anesthesia in high altitude,but it is clear that if the actual MAC (i.e.MACage) would have been monitored and compared,the results would have been different.Further study will be required taking these aspects into the account before we discard the reliability of MAC in the high altitude as a guide to depth of anesthesia as well as its relation with BIS.

Figure 1:lmages of anesthesia gas monitor displaying the variation of minimum alveolar concentration (MAC) value displayed for different ages.

Habib Md Reazaul Karim*

Department of Anaesthesiology and Critical Care,All India Institute of Medical Sciences,Raipur,India

*Correspondence to:Habib Md Reazaul Karim,MD,drhabibkarim@gmail.com.

orcid:0000-0002-6632-0491 (Habib Md Reazaul Karim)

doi:10.4103/2045-9912.260654

How to cite this article:Karim HMR.Minimum alveolar concentration based anesthesia in high altitude and anesthetic over dose:result needs cautious acceptance.Med Gas Res.2019;9(2):107.

Copyright license agreement:The Copyright License Agreement has been signed by the author before publication.

Plagiarism check:Checked twice by iThenticate.

Peer review:Externally peer reviewed.

Open access statement:This is an open access journal,and articles are distributed under the terms of the Cr eative Commons Attribution-NonCommercial-ShareAlike 4.0 License,which allows others to r emix,tweak,and build upon the work non-commer cially,as long as appropriate credit is given and the new creations are licensed under the identical terms.